CVE-2011-4878
- State
- Published
- Severity
- Not scored
- Published
- Feb 3, 2012
- Updated
- Aug 7, 2024
- Reserved
- Dec 21, 2011
Description
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
Scores
The record has no CVSS score.
Weaknesses
The record names no weakness.
Affected Products
| Product | Versions |
|---|---|
n/an/a |
|
References
- http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf
- http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf
- 18166exploit
- simatic-miniweb-directory-traversal(71452)vdb-entry
- http://aluigi.org/adv/winccflex_1-adv.txt
- 77383vdb-entry
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf