CVE-2018-4842
- State
- Published
- Severity
- Not scored
- Published
- Jun 14, 2018
- Updated
- Aug 5, 2024
- Reserved
- Jan 2, 2018
Description
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Scores
The record has no CVSS score.
Weaknesses
- CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Affected Products
| Product | Versions |
|---|---|
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)Siemens |
|
SCALANCE X-200RNA switch familySiemens |
|
SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)Siemens |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.