CVE-2018-4842

State
Published
Severity
Not scored
Published
Jun 14, 2018
Updated
Aug 5, 2024
Reserved
Jan 2, 2018

Read the record on cve.org

Description

A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Scores

The record has no CVSS score.

Weaknesses

  • CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Affected Products

ProductVersions
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)Siemens
  • All versions < V5.4.1Affected
SCALANCE X-200RNA switch familySiemens
  • All versions < V3.2.7Affected
SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)Siemens
  • All versions < V4.1.3Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.