CVE-2018-4844

State
Published
Severity
Not scored
Published
Mar 20, 2018
Updated
Sep 17, 2024
Reserved
Jan 2, 2018

Read the record on cve.org

Description

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Scores

The record has no CVSS score.

Weaknesses

Affected Products

ProductVersions
SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOSSiemens AG
  • SIMATIC WinCC OA UI for Android : All versions < V3.15.10Affected
  • SIMATIC WinCC OA UI for iOS : All versions < V3.15.10Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.