CVE-2019-10923

State
Published
Severity
7.5 High
Published
Oct 10, 2019
Updated
Feb 11, 2025
Reserved
Apr 8, 2019

Read the record on cve.org

Description

An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.

Scores

CVSSScoreVectorSource
3.17.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csiemens

Weaknesses

  • CWE-400 Uncontrolled Resource Consumption

Affected Products

ProductVersions
Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet ControllerSiemens
  • All versions < V4.1.1 Patch 05Affected
Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200Siemens
  • All versions < V4.5.0 Patch 01Affected
Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200PSiemens
  • All versions < V4.5.0Affected
SCALANCE X-200IRT family (incl. SIPLUS NET variants)Siemens
  • All versions < V5.2.1Affected
SIMATIC CP 1604Siemens
  • All versions < V2.8Affected
SIMATIC CP 1616Siemens
  • All versions < V2.8Affected
SIMATIC ET 200M (incl. SIPLUS variants)Siemens
  • All versionsAffected
SIMATIC ET 200MP IM 155-5 PN HFSiemens
  • before V4.2.0Affected
SIMATIC ET 200MP IM 155-5 PN STSiemens
  • before V4.1.0Affected
SIMATIC ET 200pro IM 154-3 PN HFSiemens
  • all versionsAffected
SIMATIC ET 200pro IM 154-4 PN HFSiemens
  • all versionsAffected
SIMATIC ET 200pro IM 154-8 PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIMATIC ET 200pro IM 154-8F PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIMATIC ET 200pro IM 154-8FX PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIMATIC ET 200S IM 151-8 PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIMATIC ET 200S IM 151-8F PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIMATIC ET 200SP IM 155-6 PN HFSiemens
  • before V4.2.0Affected
SIMATIC ET 200SP IM 155-6 PN STSiemens
  • before V4.1.0Affected
SIMATIC ET 200SP IM 155-6 PN ST BASiemens
  • before V4.1.0Affected
SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 4AO U/I 4xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12Siemens
  • All versionsAffected
SIMATIC ET200ecoPN: IO-Link MasterSiemens
  • All versionsAffected
SIMATIC ET200S (incl. SIPLUS variants)Siemens
  • All versionsAffected
SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)Siemens
  • All versionsAffected
SIMATIC S7-300 CPU 314C-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 315-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 315F-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 315T-3 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 317-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 317F-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 317T-3 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 317TF-3 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 319-3 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-300 CPU 319F-3 PN/DPSiemens
  • All versions < V3.2.17Affected
SIMATIC S7-400 CPU 412-2 PN V7Siemens
  • before V7.0.3Affected
SIMATIC S7-400 CPU 414-3 PN/DP V7Siemens
  • before V7.0.3Affected
SIMATIC S7-400 CPU 414F-3 PN/DP V7Siemens
  • before V7.0.3Affected
SIMATIC S7-400 CPU 416-3 PN/DP V7Siemens
  • before V7.0.3Affected
SIMATIC S7-400 CPU 416F-3 PN/DP V7Siemens
  • before V7.0.3Affected
SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)Siemens
  • all versionsAffected
SIMATIC WinAC RTX 2010Siemens
  • All versions < V2010 SP3Affected
SIMATIC WinAC RTX F 2010Siemens
  • All versions < V2010 SP3Affected
SIMOTIONSiemens
  • All versionsAffected
SINAMICS DCMSiemens
  • All versions < V1.5 HF1Affected
SINAMICS DCPSiemens
  • All versions < V1.3Affected
SINAMICS G110M V4.7 Control UnitSiemens
  • All versions < V4.7 SP10 HF5Affected
SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)Siemens
  • All versions < V4.7 SP10 HF5Affected
SINAMICS G130Siemens
  • before V4.7 HF29Affected
SINAMICS G150Siemens
  • before V4.7 HF29Affected
SINAMICS GH150 V4.7 Control UnitSiemens
  • All versionsAffected
SINAMICS GL150 V4.7 Control UnitSiemens
  • All versionsAffected
SINAMICS GM150 V4.7 Control UnitSiemens
  • All versionsAffected
SINAMICS S110 Control UnitSiemens
  • All versionsAffected
SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)Siemens
  • All versions < V4.7 HF34Affected
SINAMICS S150Siemens
  • before V4.7 HF29Affected
SINAMICS SL150 V4.7 Control UnitSiemens
  • All versions < V4.7 HF33Affected
SINAMICS SM120 V4.7 Control UnitSiemens
  • All versionsAffected
SINUMERIK 828DSiemens
  • All versions < V4.8 SP5Affected
SINUMERIK 840D slSiemens
  • All versions < V4.8 SP5Affected
SIPLUS ET 200MP IM 155-5 PN HFSiemens
  • before V4.2.0Affected
SIPLUS ET 200MP IM 155-5 PN HFSiemens
  • before V4.2.0Affected
SIPLUS ET 200MP IM 155-5 PN HF T1 RAILSiemens
  • before V4.2.0Affected
SIPLUS ET 200MP IM 155-5 PN STSiemens
  • before V4.1.0Affected
SIPLUS ET 200MP IM 155-5 PN ST TX RAILSiemens
  • before V4.1.0Affected
SIPLUS ET 200S IM 151-8 PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIPLUS ET 200S IM 151-8F PN/DP CPUSiemens
  • All versions < V3.2.17Affected
SIPLUS ET 200SP IM 155-6 PN HFSiemens
  • before V4.2.0Affected
SIPLUS ET 200SP IM 155-6 PN HFSiemens
  • before V4.2.0Affected
SIPLUS ET 200SP IM 155-6 PN HF T1 RAILSiemens
  • before V4.2.0Affected
SIPLUS ET 200SP IM 155-6 PN STSiemens
  • before V4.1.0Affected
SIPLUS ET 200SP IM 155-6 PN ST BASiemens
  • before V4.1.0Affected
SIPLUS ET 200SP IM 155-6 PN ST BA TX RAILSiemens
  • before V4.1.0Affected
SIPLUS ET 200SP IM 155-6 PN ST TX RAILSiemens
  • before V4.1.0Affected
SIPLUS S7-300 CPU 314C-2 PN/DPSiemens
  • All versions < V3.3.17Affected
SIPLUS S7-300 CPU 315-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIPLUS S7-300 CPU 315F-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIPLUS S7-300 CPU 317-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIPLUS S7-300 CPU 317F-2 PN/DPSiemens
  • All versions < V3.2.17Affected
SIPLUS S7-400 CPU 414-3 PN/DP V7Siemens
  • before V7.0.3Affected
SIPLUS S7-400 CPU 416-3 PN/DP V7Siemens
  • before V7.0.3Affected

References