CVE-2019-11891
Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
- State
- Published
- Severity
- 8.0 High
- Published
- May 29, 2019
- Updated
- Sep 16, 2024
- Reserved
- May 13, 2019
Description
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.0 | 8.0 High | CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H | bosch |
Weaknesses
- CWE-266 Incorrect Privilege Assignment
Affected Products
| Product | Versions |
|---|---|
Smart Home ControllerBosch |
|
References