CVE-2019-18336

State
Published
Severity
7.5 High
Published
Mar 10, 2020
Updated
Jun 2, 2026
Reserved
Oct 23, 2019

Read the record on cve.org

Description

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.

Scores

CVSSScoreVectorSource
3.17.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HCISA-ADP

Weaknesses

  • CWE-400 Uncontrolled Resource Consumption

Affected Products

ProductVersions
SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)Siemens AG
  • All versions < V3.X.17Affected
SIMATIC TDC CP51M1Siemens AG
  • All versions < V1.1.8Affected
SIMATIC TDC CPU555Siemens AG
  • All versions < V1.1.1Affected
SINUMERIK 840D slSiemens AG
  • All versions < V4.8.6Affected
SINUMERIK 840D slSiemens AG
  • All versions < V4.94Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.