CVE-2020-10270

RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard

State
Published
Severity
9.8 Critical
Published
Jun 24, 2020
Updated
Sep 17, 2024
Reserved
Mar 10, 2020

Read the record on cve.org

Description

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

Scores

CVSSScoreVectorSource
3.09.8 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HAlias

Weaknesses

Affected Products

ProductVersions
MiR100Mobile Industrial Robots A/S
  • v2.8.1.1 and beforeAffected