CVE-2020-12149

OS Command Injection - Management File Upload

State
Published
Severity
6.8 Medium
Published
Dec 11, 2020
Updated
Sep 16, 2024
Reserved
Apr 24, 2020

Read the record on cve.org

Description

The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.

Scores

CVSSScoreVectorSource
3.16.8 MediumCVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:HSilver Peak

Weaknesses

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Affected Products

ProductVersions
ECOSSilver Peak Systems, Inc.
  • All current ECOS versions prior to 8.1.9.15Affected
  • 8.3.0.8Affected
  • 8.3.1.2Affected
  • 8.3.2.0Affected
  • 9.0.2.0Affected
  • and 9.1.0.0Affected