CVE-2021-25664
- State
- Published
- Severity
- 8.7 High
- Published
- Apr 22, 2021
- Updated
- Mar 11, 2025
- Reserved
- Jan 21, 2021
Description
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 4.0 | 8.7 High | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N | siemens |
| 3.1 | 7.5 High | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C | siemens |
Weaknesses
- CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')
Affected Products
| Product | Versions |
|---|---|
Capital Embedded AR Classic 431-422Siemens |
|
Capital Embedded AR Classic R20-11Siemens |
|
Nucleus NETSiemens |
|
Nucleus ReadyStart V3Siemens |
|
Nucleus ReadyStart V4Siemens |
|
Nucleus Source CodeSiemens |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.