CVE-2022-23034

State
Published
Severity
Not scored
Published
Jan 25, 2022
Updated
Aug 3, 2024
Reserved
Jan 10, 2022

Read the record on cve.org

Description

A PV guest could DoS Xen while unmapping a grant To address XSA-380, reference counting was introduced for grant mappings for the case where a PV guest would have the IOMMU enabled. PV guests can request two forms of mappings. When both are in use for any individual mapping, unmapping of such a mapping can be requested in two steps. The reference count for such a mapping would then mistakenly be decremented twice. Underflow of the counters gets detected, resulting in the triggering of a hypervisor bug check.

Scores

The record has no CVSS score.

Weaknesses

The record names no weakness.

Affected Products

ProductVersions
xenXen
  • consult Xen advisory XSA-394Unknown

References