CVE-2022-31491

State
Published
Severity
10.0 Critical
Published
Aug 22, 2025
Updated
Aug 22, 2025
Reserved
May 23, 2022

Read the record on cve.org

Description

Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this to run arbitrary code immediately regardless of any managed UPS state or presence.

Scores

CVSSScoreVectorSource
3.110.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:HCISA-ADP

Weaknesses

  • CWE-749 Exposed Dangerous Method or Function
  • CWE-94 Improper Control of Generation of Code ('Code Injection')

Affected Products

ProductVersions
n/an/a
  • n/aAffected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.