CVE-2022-36362
- State
- Published
- Severity
- 7.5 High
- Published
- Oct 11, 2022
- Updated
- Oct 8, 2024
- Reserved
- Jul 21, 2022
Description
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 7.5 High | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C | siemens |
Weaknesses
- CWE-20 Improper Input Validation
Affected Products
| Product | Versions |
|---|---|
LOGO! 12/24RCESiemens |
|
LOGO! 12/24RCESiemens |
|
LOGO! 12/24RCEoSiemens |
|
LOGO! 12/24RCEoSiemens |
|
LOGO! 230RCESiemens |
|
LOGO! 230RCESiemens |
|
LOGO! 230RCEoSiemens |
|
LOGO! 230RCEoSiemens |
|
LOGO! 24CESiemens |
|
LOGO! 24CESiemens |
|
LOGO! 24CEoSiemens |
|
LOGO! 24CEoSiemens |
|
LOGO! 24RCESiemens |
|
LOGO! 24RCESiemens |
|
LOGO! 24RCEoSiemens |
|
LOGO! 24RCEoSiemens |
|
SIPLUS LOGO! 12/24RCESiemens |
|
SIPLUS LOGO! 12/24RCESiemens |
|
SIPLUS LOGO! 12/24RCEoSiemens |
|
SIPLUS LOGO! 12/24RCEoSiemens |
|
SIPLUS LOGO! 230RCESiemens |
|
SIPLUS LOGO! 230RCESiemens |
|
SIPLUS LOGO! 230RCEoSiemens |
|
SIPLUS LOGO! 230RCEoSiemens |
|
SIPLUS LOGO! 24CESiemens |
|
SIPLUS LOGO! 24CESiemens |
|
SIPLUS LOGO! 24CEoSiemens |
|
SIPLUS LOGO! 24CEoSiemens |
|
SIPLUS LOGO! 24RCESiemens |
|
SIPLUS LOGO! 24RCESiemens |
|
SIPLUS LOGO! 24RCEoSiemens |
|
SIPLUS LOGO! 24RCEoSiemens |
|
References