CVE-2022-41657
- State
- Published
- Severity
- 9.8 Critical
- Published
- Oct 31, 2022
- Updated
- Apr 16, 2025
- Reserved
- Sep 29, 2022
Description
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 9.8 Critical | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | icscert |
Weaknesses
- CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Affected Products
| Product | Versions |
|---|---|
InfraSuite Device MasterDelta Electronics |
|
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07government-resource
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.