CVE-2022-41776
- State
- Published
- Severity
- 7.5 High
- Published
- Oct 31, 2022
- Updated
- Apr 16, 2025
- Reserved
- Sep 29, 2022
Description
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 7.5 High | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N | icscert |
Weaknesses
- CWE-306 Missing Authentication for Critical Function
Affected Products
| Product | Versions |
|---|---|
InfraSuite Device MasterDelta Electronics |
|
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07government-resource