CVE-2022-47767
- State
- Published
- Severity
- 9.8 Critical
- Published
- Jan 25, 2023
- Updated
- Apr 1, 2025
- Reserved
- Dec 21, 2022
Description
A backdoor in Solar-Log Gateway products allows remote access via web panel gaining super administration privileges to the attacker. This affects Solar-Log devices that use firmware version v4.2.7 up to v5.1.1 (included). This does not exist in SL 200, 500, 1000 / fixed in 4.2.8 for SL 250, 300, 1200, 2000, SL 50 Gateway / fixed in 5.1.2 / 6.0.0 for SL Base.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 9.8 Critical | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | CISA-ADP |
Weaknesses
- CWE-912 Hidden Functionality
Affected Products
| Product | Versions |
|---|---|
n/an/a |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.