CVE-2023-22441
- State
- Published
- Severity
- 8.6 High
- Published
- May 10, 2023
- Updated
- Jan 28, 2025
- Reserved
- Mar 15, 2023
Description
Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 8.6 High | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H | CISA-ADP |
Weaknesses
- CWE-306 Missing Authentication for Critical Function
Affected Products
| Product | Versions |
|---|---|
SkyBridge MB-A200 and SkyBridge BASIC MB-A130Seiko Solutions Inc. |
|
References
- https://www.seiko-sol.co.jp/archives/73969/
- https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/
- https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/
- https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/
- https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/
- https://jvn.jp/en/jp/JVN40604023/
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.