CVE-2023-2778
Rockwell Automation FactoryTalk Transaction Manager Vulnerable to Denial-Of-Service
- State
- Published
- Severity
- 7.5 High
- Published
- Jun 13, 2023
- Updated
- Mar 5, 2025
- Reserved
- May 17, 2023
Description
A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 7.5 High | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | Rockwell |
Weaknesses
- CWE-400 Uncontrolled Resource Consumption
Affected Products
| Product | Versions |
|---|---|
FactoryTalk Transaction ManagerRockwell Automation |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.