Description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device.

Scores

CVSSScoreVectorSource
3.19.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csiemens

Weaknesses

Affected Products

ProductVersions
SIMATIC CN 4100Siemens
  • All versions < V2.7Affected