CVE-2024-30191
- State
- Published
- Severity
- 8.4 High
- Published
- Apr 9, 2024
- Updated
- Aug 27, 2024
- Reserved
- Mar 25, 2024
Description
A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 3 "Override client’s security context" of CVE-2022-47522.
Affected devices can be tricked into associating a newly negotiated, attacker-controlled, security context with frames belonging to a victim. This could allow a physically proximate attacker to decrypt frames meant for the victim.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 8.4 High | CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H | siemens |
Weaknesses
- CWE-290 Authentication Bypass by Spoofing
Affected Products
| Product | Versions |
|---|---|
SCALANCE W1748-1 M12Siemens |
|
SCALANCE W1748-1 M12Siemens |
|
SCALANCE W1788-1 M12Siemens |
|
SCALANCE W1788-2 EEC M12Siemens |
|
SCALANCE W1788-2 M12Siemens |
|
SCALANCE W1788-2IA M12Siemens |
|
SCALANCE W721-1 RJ45Siemens |
|
SCALANCE W721-1 RJ45Siemens |
|
SCALANCE W722-1 RJ45Siemens |
|
SCALANCE W722-1 RJ45Siemens |
|
SCALANCE W722-1 RJ45Siemens |
|
SCALANCE W734-1 RJ45Siemens |
|
SCALANCE W734-1 RJ45Siemens |
|
SCALANCE W734-1 RJ45Siemens |
|
SCALANCE W734-1 RJ45 (USA)Siemens |
|
SCALANCE W738-1 M12Siemens |
|
SCALANCE W738-1 M12Siemens |
|
SCALANCE W748-1 M12Siemens |
|
SCALANCE W748-1 M12Siemens |
|
SCALANCE W748-1 RJ45Siemens |
|
SCALANCE W748-1 RJ45Siemens |
|
SCALANCE W761-1 RJ45Siemens |
|
SCALANCE W761-1 RJ45Siemens |
|
SCALANCE W774-1 M12 EECSiemens |
|
SCALANCE W774-1 M12 EECSiemens |
|
SCALANCE W774-1 RJ45Siemens |
|
SCALANCE W774-1 RJ45Siemens |
|
SCALANCE W774-1 RJ45Siemens |
|
SCALANCE W774-1 RJ45Siemens |
|
SCALANCE W774-1 RJ45 (USA)Siemens |
|
SCALANCE W778-1 M12Siemens |
|
SCALANCE W778-1 M12Siemens |
|
SCALANCE W778-1 M12 EECSiemens |
|
SCALANCE W778-1 M12 EEC (USA)Siemens |
|
SCALANCE W786-1 RJ45Siemens |
|
SCALANCE W786-1 RJ45Siemens |
|
SCALANCE W786-2 RJ45Siemens |
|
SCALANCE W786-2 RJ45Siemens |
|
SCALANCE W786-2 RJ45Siemens |
|
SCALANCE W786-2 SFPSiemens |
|
SCALANCE W786-2 SFPSiemens |
|
SCALANCE W786-2IA RJ45Siemens |
|
SCALANCE W786-2IA RJ45Siemens |
|
SCALANCE W788-1 M12Siemens |
|
SCALANCE W788-1 M12Siemens |
|
SCALANCE W788-1 RJ45Siemens |
|
SCALANCE W788-1 RJ45Siemens |
|
SCALANCE W788-2 M12Siemens |
|
SCALANCE W788-2 M12Siemens |
|
SCALANCE W788-2 M12 EECSiemens |
|
SCALANCE W788-2 M12 EECSiemens |
|
SCALANCE W788-2 M12 EECSiemens |
|
SCALANCE W788-2 RJ45Siemens |
|
SCALANCE W788-2 RJ45Siemens |
|
SCALANCE W788-2 RJ45Siemens |
|
SCALANCE WAM763-1Siemens |
|
SCALANCE WAM766-1 (EU)Siemens |
|
SCALANCE WAM766-1 (US)Siemens |
|
SCALANCE WAM766-1 EEC (EU)Siemens |
|
SCALANCE WAM766-1 EEC (US)Siemens |
|
SCALANCE WUM763-1Siemens |
|
SCALANCE WUM763-1Siemens |
|
SCALANCE WUM766-1 (EU)Siemens |
|
SCALANCE WUM766-1 (US)Siemens |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.