CVE-2024-43781
- State
- Published
- Severity
- 6.8 Medium
- Published
- Sep 10, 2024
- Updated
- Sep 10, 2024
- Reserved
- Aug 16, 2024
Description
A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 4.0 | 6.8 Medium | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N | siemens |
| 3.1 | 5.5 Medium | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C | siemens |
Weaknesses
- CWE-532 Insertion of Sensitive Information into Log File
Affected Products
| Product | Versions |
|---|---|
SINUMERIK 828D V4Siemens |
|
SINUMERIK 840D sl V4Siemens |
|
SINUMERIK ONESiemens |
|
SINUMERIK ONESiemens |
|
References