CVE-2025-26856

State
Published
Severity
7.2 High
Published
Feb 20, 2025
Updated
Feb 20, 2025
Reserved
Feb 17, 2025

Read the record on cve.org

Description

Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If an attacker logs in to the affected product with an administrative account and manipulates requests for a certain screen operation, an arbitrary OS command may be executed. This vulnerability was reported on a different screen operation from CVE-2025-20617.

Scores

CVSSScoreVectorSource
3.07.2 HighCVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hjpcert

Weaknesses

  • CWE-78 Improper neutralization of special elements used in an OS command ('OS Command Injection')

Affected Products

ProductVersions
UD-LT2I-O DATA DEVICE, INC.
  • firmware Ver.1.00.008_SE and earlierAffected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.