CVE-2025-30645
Junos OS: SRX Series: Transmission of specific control traffic sent out of a DS-Lite tunnel results in flowd crash
- State
- Published
- Severity
- 8.7 High
- Published
- Apr 9, 2025
- Updated
- Apr 24, 2025
- Reserved
- Mar 24, 2025
Description
A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS). Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition.
On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts.
This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 4.0 | 8.7 High | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/AU:Y/R:A/V:C/RE:M/U:Green | juniper |
| 3.1 | 7.5 High | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | juniper |
Weaknesses
- CWE-476 NULL Pointer Dereference
Affected Products
| Product | Versions |
|---|---|
Junos OSJuniper Networks |
|
References
- https://supportportal.juniper.net/JSA96455vendor-advisory