CVE-2025-3498

Unauthenticated modification of Radiflow iSAP Smart Collector configuration

State
Published
Severity
9.9 Critical
Published
Jul 9, 2025
Updated
Jul 9, 2025
Reserved
Apr 10, 2025

Read the record on cve.org

Description

An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).

Scores

CVSSScoreVectorSource
3.19.9 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:LENISA

Weaknesses

  • CWE-306 Missing Authentication for Critical Function

Affected Products

ProductVersions
iSAP Smart CollectorRadiflow
  • 1.20 to before 3.02-1Affected