CVE-2025-40568

State
Published
Severity
5.3 Medium
Published
Jun 10, 2025
Updated
Jan 13, 2026
Reserved
Apr 16, 2025

Read the record on cve.org

Description

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions.

Scores

CVSSScoreVectorSource
4.05.3 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:Nsiemens
3.14.3 MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Lsiemens

Weaknesses

Affected Products

ProductVersions
RUGGEDCOM RST2428PSiemens
  • before V3.2Affected
SCALANCE XCH328Siemens
  • before V3.2Affected
SCALANCE XCM324Siemens
  • before V3.2Affected
SCALANCE XCM328Siemens
  • before V3.2Affected
SCALANCE XCM332Siemens
  • before V3.2Affected
SCALANCE XRH334 (24 V DC, 8xFO, CC)Siemens
  • before V3.2Affected
SCALANCE XRM334 (230 V AC, 12xFO)Siemens
  • before V3.2Affected
SCALANCE XRM334 (230 V AC, 8xFO)Siemens
  • before V3.2Affected
SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)Siemens
  • before V3.2Affected
SCALANCE XRM334 (24 V DC, 12xFO)Siemens
  • before V3.2Affected
SCALANCE XRM334 (24 V DC, 8xFO)Siemens
  • before V3.2Affected
SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)Siemens
  • before V3.2Affected
SCALANCE XRM334 (2x230 V AC, 12xFO)Siemens
  • before V3.2Affected
SCALANCE XRM334 (2x230 V AC, 8xFO)Siemens
  • before V3.2Affected
SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)Siemens
  • before V3.2Affected