CVE-2025-40939

State
Published
Severity
5.1 Medium
Published
Dec 9, 2025
Updated
Dec 9, 2025
Reserved
Apr 16, 2025

Read the record on cve.org

Description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device contains a USB port which allows unauthenticated connections. This could allow an attacker with physical access to the device to trigger reboot that could cause denial of service condition.

Scores

CVSSScoreVectorSource
4.05.1 MediumCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:Nsiemens
3.14.6 MediumCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsiemens

Weaknesses

Affected Products

ProductVersions
SIMATIC CN 4100Siemens
  • before V4.0.1Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.