CVE-2025-40944

State
Published
Severity
8.7 High
Published
Jan 13, 2026
Updated
Jun 9, 2026
Reserved
Apr 16, 2025

Read the record on cve.org

Description

A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions < V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions < V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions >= V4.2.0 < V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions < V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions < V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions >= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions < V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state.

This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation.

Scores

CVSSScoreVectorSource
4.08.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:Nsiemens
3.17.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsiemens

Weaknesses

  • CWE-400 Uncontrolled Resource Consumption

Affected Products

ProductVersions
SIMATIC ET 200AL IM 157-1 PNSiemens
  • all versionsAffected
SIMATIC ET 200MP IM 155-5 PN HFSiemens
  • V4.2.0 and laterAffected
SIMATIC ET 200SP IM 155-6 MF HFSiemens
  • all versionsAffected
SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)Siemens
  • before V1.3Affected
SIMATIC ET 200SP IM 155-6 PN R1Siemens
  • before V6.0.1Affected
SIMATIC ET 200SP IM 155-6 PN/2 HFSiemens
  • V4.2.0 to before V4.2.5Affected
SIMATIC ET 200SP IM 155-6 PN/3 HFSiemens
  • before V4.2.2Affected
SIMATIC PN/MF CouplerSiemens
  • all versionsAffected
SIMATIC PN/PN CouplerSiemens
  • before V6.0.0Affected
SIPLUS ET 200MP IM 155-5 PN HFSiemens
  • V4.2.0 and laterAffected
SIPLUS ET 200MP IM 155-5 PN HFSiemens
  • V4.2.0 and laterAffected
SIPLUS ET 200MP IM 155-5 PN HF T1 RAILSiemens
  • V4.2.0 and laterAffected
SIPLUS ET 200SP IM 155-6 PN HFSiemens
  • V4.2.0 to before V4.2.5Affected
SIPLUS ET 200SP IM 155-6 PN HFSiemens
  • V4.2.0 to before V4.2.5Affected
SIPLUS ET 200SP IM 155-6 PN HF T1 RAILSiemens
  • V4.2.0 to before V4.2.5Affected
SIPLUS ET 200SP IM 155-6 PN HF TX RAILSiemens
  • V4.2.0 to before V4.2.5Affected
SIPLUS NET PN/PN CouplerSiemens
  • before V6.0.0Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.