CVE-2025-41690

Endress+Hauser: Proline 10 Maintenance credentials may be exposed under certain conditions

State
Published
Severity
7.4 High
Published
Sep 2, 2025
Updated
Sep 2, 2025
Reserved
Apr 16, 2025

Read the record on cve.org

Description

A low-privileged attacker in bluetooth range may be able to access the password of a higher-privilege user (Maintenance) by viewing the device’s event log. This vulnerability could allow the Operator to authenticate as the Maintenance user, thereby gaining unauthorized access to sensitive configuration settings and the ability to modify device parameters.

Scores

CVSSScoreVectorSource
3.17.4 HighCVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:HCERTVDE

Weaknesses

  • CWE-532 Insertion of Sensitive Information into Log File

Affected Products

ProductVersions
Promag 10 with HARTEndress+Hauser
  • before 01.00.06Affected
Promag 10 with IO-LinkEndress+Hauser
  • before 01.00.02Affected
Promag 10 with ModbusEndress+Hauser
  • before 01.00.06Affected
Promass 10 with HARTEndress+Hauser
  • before 01.00.06Affected
Promass 10 with IO-LinkEndress+Hauser
  • before 01.00.02Affected
Promass 10 with ModbusEndress+Hauser
  • before 01.00.06Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.