CVE-2025-52947

Junos OS: ACX Series: When 'hot-standby' mode is configured for an L2 circuit, interface flap causes the FEB to crash

State
Published
Severity
7.1 High
Published
Jul 11, 2025
Updated
Jul 11, 2025
Reserved
Jun 23, 2025

Read the record on cve.org

Description

An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS).

On ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when 'hot-standby' mode is configured for the L2 circuit.

This issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096:

* all versions before 21.2R3-S9.

Scores

CVSSScoreVectorSource
4.07.1 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/R:A/RE:M/U:Greenjuniper
3.16.5 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hjuniper

Weaknesses

  • CWE-755 Improper Handling of Exceptional Conditions

Affected Products

ProductVersions
Junos OSJuniper Networks
  • before 21.2R3-S9Affected

References