CVE-2025-5946
RCE via the poller reload feature available only to user with high privilege
- State
- Published
- Severity
- 7.2 High
- Published
- Oct 14, 2025
- Updated
- Oct 14, 2025
- Reserved
- Jun 9, 2025
Description
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.
This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 7.2 High | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | Centreon |
Weaknesses
- CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Affected Products
| Product | Versions |
|---|---|
Infra MonitoringCentreon |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.