CVE-2026-111221

Netgate pfSense CE through 2.9.0 Command Injection via RADIUS Secret mpd.conf Injection

State
Published
Severity
7.5 High
Published
Oct 15, 2026
Updated
Oct 26, 2026
Reserved
Oct 15, 2026

Read the record on cve.org

Description

Netgate pfSense CE through 2.9.0 contains a configuration injection vulnerability that allows authenticated WebGUI users to inject mpd5 commands by submitting an unescaped RADIUS shared secret. Attackers with L2TP or PPPoE Server edit privileges can POST a secret containing a quote and newline to vpn_l2tp.php or services_pppoe_edit.php, appending an up-script that executes as root when a session starts.

Scores

CVSSScoreVectorSource
4.07.5 HighCVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NVulnCheck
3.16.6 MediumCVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:HVulnCheck

Weaknesses

  • CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection')

Affected Products

ProductVersions
pfSense CENetgate
  • 2.9.0 and earlierAffected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.