CVE-2026-22319
Stack-Based Buffer Overflow in File Install Parameter Handling
- State
- Published
- Severity
- 4.9 Medium
- Published
- Mar 18, 2026
- Updated
- Mar 18, 2026
- Reserved
- Jan 7, 2026
Description
A stack-based buffer overflow in the device's file installation workflow allows a high-privileged attacker to send oversized POST parameters that overflow a fixed-size stack buffer within an internal process, resulting in a DoS attack.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 4.9 Medium | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H | CERTVDE |
Weaknesses
- CWE-121 Stack-based Buffer Overflow
Affected Products
| Product | Versions |
|---|---|
FL SWITCH 2005Phoenix Contact |
|
FL SWITCH 2008Phoenix Contact |
|
FL SWITCH 2016Phoenix Contact |
|
FL SWITCH 2105Phoenix Contact |
|
FL SWITCH 2108Phoenix Contact |
|
FL SWITCH 2116Phoenix Contact |
|
FL SWITCH 2204-2TC-2SFXPhoenix Contact |
|
FL SWITCH 2205Phoenix Contact |
|
FL SWITCH 2206-2FXPhoenix Contact |
|
FL SWITCH 2206-2FX SMPhoenix Contact |
|
FL SWITCH 2206-2FX SM STPhoenix Contact |
|
FL SWITCH 2206-2FX STPhoenix Contact |
|
FL SWITCH 2206-2SFXPhoenix Contact |
|
FL SWITCH 2206-2SFX PNPhoenix Contact |
|
FL SWITCH 2206C-2FXPhoenix Contact |
|
FL SWITCH 2207-FXPhoenix Contact |
|
FL SWITCH 2207-FX SMPhoenix Contact |
|
FL SWITCH 2208Phoenix Contact |
|
FL SWITCH 2208 PNPhoenix Contact |
|
FL SWITCH 2208CPhoenix Contact |
|
FL SWITCH 2212-2TC-2SFXPhoenix Contact |
|
FL SWITCH 2214-2FXPhoenix Contact |
|
FL SWITCH 2214-2FX SMPhoenix Contact |
|
FL SWITCH 2214-2SFXPhoenix Contact |
|
FL SWITCH 2214-2SFX PNPhoenix Contact |
|
FL SWITCH 2216Phoenix Contact |
|
FL SWITCH 2216 PNPhoenix Contact |
|
FL SWITCH 2304-2GC-2SFPPhoenix Contact |
|
FL SWITCH 2306-2SFPPhoenix Contact |
|
FL SWITCH 2306-2SFP PNPhoenix Contact |
|
FL SWITCH 2308Phoenix Contact |
|
FL SWITCH 2308 PNPhoenix Contact |
|
FL SWITCH 2312-2GC-2SFPPhoenix Contact |
|
FL SWITCH 2314-2SFPPhoenix Contact |
|
FL SWITCH 2314-2SFP PNPhoenix Contact |
|
FL SWITCH 2316Phoenix Contact |
|
FL SWITCH 2316 PNPhoenix Contact |
|
FL SWITCH 2404-2TC-2SFXPhoenix Contact |
|
FL SWITCH 2406-2SFXPhoenix Contact |
|
FL SWITCH 2406-2SFX PNPhoenix Contact |
|
FL SWITCH 2408Phoenix Contact |
|
FL SWITCH 2408 PNPhoenix Contact |
|
FL SWITCH 2412-2TC-2SFXPhoenix Contact |
|
FL SWITCH 2414-2SFXPhoenix Contact |
|
FL SWITCH 2414-2SFX PNPhoenix Contact |
|
FL SWITCH 2416Phoenix Contact |
|
FL SWITCH 2416 PNPhoenix Contact |
|
FL SWITCH 2504-2GC-2SFPPhoenix Contact |
|
FL SWITCH 2506-2SFPPhoenix Contact |
|
FL SWITCH 2506-2SFP PNPhoenix Contact |
|
FL SWITCH 2508Phoenix Contact |
|
FL SWITCH 2508 PNPhoenix Contact |
|
FL SWITCH 2512-2GC-2SFPPhoenix Contact |
|
FL SWITCH 2514-2SFPPhoenix Contact |
|
FL SWITCH 2514-2SFP PNPhoenix Contact |
|
FL SWITCH 2516Phoenix Contact |
|
FL SWITCH 2516 PNPhoenix Contact |
|
FL SWITCH 2608Phoenix Contact |
|
FL SWITCH 2608 PNPhoenix Contact |
|
FL SWITCH 2708Phoenix Contact |
|
FL SWITCH 2708 PNPhoenix Contact |
|
FL SWITCH 2303-8SP1Phoenix Contact |
|
FL NAT 2008Phoenix Contact |
|
FL NAT 2208Phoenix Contact |
|
FL NAT 2304-2GC-2SFPPhoenix Contact |
|
FL SWITCH 2008FPhoenix Contact |
|
FL SWITCH 2316/K1Phoenix Contact |
|
FL SWITCH 2506-2SFP/K1Phoenix Contact |
|
FL SWITCH 2508/K1Phoenix Contact |
|
FL SWITCH TSN 2316Phoenix Contact |
|
FL SWITCH TSN 2312-2GC-2SFPPhoenix Contact |
|
FL SWITCH TSN 2314-2SFPPhoenix Contact |
|
FL SWITCH 5924-4GCPhoenix Contact |
|
FL SWITCH 5916-8GC-4SFP+Phoenix Contact |
|
FL SWITCH 5924SFP-4GCPhoenix Contact |
|
FL SWITCH 5924-4SFP+Phoenix Contact |
|
FL SWITCH 5916SFP-8GC-4SFP+Phoenix Contact |
|