CVE-2026-25599

Missing authentication and clear‑text data transmission affecting Orca heat pumps

State
Published
Severity
6.3 Medium
Published
Jun 1, 2026
Updated
Jun 1, 2026
Reserved
Feb 3, 2026

Read the record on cve.org

Description

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

Scores

CVSSScoreVectorSource
3.16.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:LENISA

Weaknesses

  • CWE-79 Improper neutralization of input during web page generation ('cross-site scripting')
  • CWE-306 Missing authentication for critical function
  • CWE-319 Cleartext transmission of sensitive information

Affected Products

ProductVersions
Orca heat pumpOrca Energy
  • before 2.1.0Affected
Orca user portalOrca Energy
  • before 1.19Affected

References