CVE-2026-25857
Tenda G300-F Command Injection via formSetWanDiag
- State
- Published
- Severity
- 8.6 High
- Published
- Feb 7, 2026
- Updated
- May 11, 2026
- Reserved
- Feb 6, 2026
Description
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 4.0 | 8.6 High | CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N | VulnCheck |
Weaknesses
- CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Affected Products
| Product | Versions |
|---|---|
Tenda G300-FShenzhen Tenda Technology |
|
References
- https://blog.evan.lat/blog/cve-2026-25857/technical-descriptionexploit
- https://www.tendacn.com/material/show/736333682028613product
- https://www.vulncheck.com/advisories/tenda-g300-f-command-injection-via-formsetwandiagthird-party-advisory
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.