CVE-2026-25857

Tenda G300-F Command Injection via formSetWanDiag

State
Published
Severity
8.6 High
Published
Feb 7, 2026
Updated
May 11, 2026
Reserved
Feb 6, 2026

Read the record on cve.org

Description

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.

Scores

CVSSScoreVectorSource
4.08.6 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NVulnCheck

Weaknesses

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Affected Products

ProductVersions
Tenda G300-FShenzhen Tenda Technology
  • 16.01.14.2 and earlierAffected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.