CVE-2026-34021

Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay

State
Published
Severity
8.6 High
Published
Jun 15, 2026
Updated
Jun 15, 2026
Reserved
Mar 25, 2026

Read the record on cve.org

Description

The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.

Scores

CVSSScoreVectorSource
4.08.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:NSEC-VLab

Weaknesses

  • CWE-294 Authentication bypass by capture-replay

Affected Products

ProductVersions
Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller)Wertheim GmbH
  • Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320Affected