CVE-2026-40058

Vulnerability Affecting Office Macro Removal in CrowdStrike Falcon Sensor for Windows

State
Published
Severity
8.8 High
Published
Sep 15, 2026
Updated
Sep 15, 2026
Reserved
Apr 8, 2026

Read the record on cve.org

Description

CrowdStrike released a security update to address a vulnerability in the Falcon sensor for Windows. The vulnerability only exists when the Microsoft Office File Malicious Macro Removal Windows policy setting is enabled and customers remain protected through the Cloud Anti-malware for Microsoft Office Files settings.

An update is available immediately for versions 7.34 and above, 7.32 LTS, and 7.16 for Windows 7/2008 R2 systems. The Falcon sensor for Mac, Linux, and Legacy Systems are not affected.

This vulnerability could expose an arbitrary file write to protected locations from an unprivileged context, potentially leading to local privilege escalation.

The CrowdStrike Laroux Malware Cleanup Tool, based off of the same feature in the CrowdStrike Falcon sensor for Windows, is also affected. An update for this tool is also available immediately.

Scores

CVSSScoreVectorSource
3.18.8 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:HCrowdStrike

Weaknesses

  • CWE-367 Time-of-check time-of-use (TOCTOU) race condition

Affected Products

ProductVersions
Falcon sensor for WindowsCrowdStrike
  • 8.10.0 to before 8.10.21408Affected
  • 7.40.0 to before 7.40.21309Affected
  • 7.39.0 to before 7.39.21113Affected
  • 7.38.0 to before 7.38.21007Affected
  • 7.37.0 to before 7.37.20912Affected
  • 7.36.0 to before 7.36.20807Affected
  • 7.35.0 to before 7.35.20712Affected
  • 7.34.0 to before 7.34.20613Affected
  • 7.33.0Affected
  • 7.32.0 to before 7.32.20410Affected
Falcon sensor for WindowsCrowdStrike
  • 7.16.0 to before 7.16.18644Affected
Laroux Cleanup ToolCrowdStrike
  • 1.0.20 to before 1.4.70.0Affected

References