CVE-2026-44107

Exposed Reboot via Modbus

State
Published
Severity
8.7 High
Published
Jul 30, 2026
Updated
Jul 30, 2026
Reserved
May 5, 2026

Read the record on cve.org

Description

A reboot of the charging controller can be triggered via Modbus TCP without authentication. Therefore, when the Modbus functionality is enabled by opening the port that CharxModbusServer is listening, an unauthenticated attacker can perform a Denial-of-Service attack.

Scores

CVSSScoreVectorSource
4.08.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NCERTVDE
3.17.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HCERTVDE

Weaknesses

  • CWE-749 Exposed Dangerous Method or Function

Affected Products

ProductVersions
CHARX SEC-3150Phoenix Contact
  • 1.0.0 to before 1.9.1Affected
CHARX SEC-3100Phoenix Contact
  • 1.0.0 to before 1.9.1Affected
CHARX SEC-3050Phoenix Contact
  • 1.0.0 to before 1.9.1Affected
CHARX SEC-3000Phoenix Contact
  • 1.0.0 to before 1.9.1Affected