CVE-2026-5777

Security Misconfiguration Vulnerability in Atom 3x Projector

State
Published
Severity
8.7 High
Published
Apr 10, 2026
Updated
Apr 10, 2026
Reserved
Apr 8, 2026

Read the record on cve.org

Description

This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this vulnerability to obtain root-level access, leading to complete compromise of the targeted device.

Scores

CVSSScoreVectorSource
4.08.7 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NCERT-In

Weaknesses

  • CWE-306 Missing authentication for critical function

Affected Products

ProductVersions
Atom 3X ProjectorEGate
  • Wed Jun 18 10:35:47 CST 2025 to before Mar Tue 10 17:57:35 CST 2026Affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.