CVE-2026-61884

Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function

State
Published
Severity
9.3 Critical
Published
Jul 24, 2026
Updated
Sep 4, 2026
Reserved
Jul 13, 2026

Read the record on cve.org

Description

The Tycon Systems TPDIN-Monitor-WEB2 ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment.

Scores

CVSSScoreVectorSource
4.09.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nicscert
3.19.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hicscert

Weaknesses

Affected Products

ProductVersions
TPDIN-Monitor-WEB2Tycon Systems
  • before 2.4.5Affected
  • 2.4.5Not affected