CVE-2026-79316
- State
- Published
- Severity
- 7.6 High
- Published
- Sep 21, 2026
- Updated
- Sep 22, 2026
- Reserved
- Aug 25, 2026
Description
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
Scores
| CVSS | Score | Vector | Source |
|---|---|---|---|
| 3.1 | 7.6 High | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L | CISA-ADP |
Weaknesses
- CWE-284 Improper Access Control
Affected Products
| Product | Versions |
|---|---|
n/an/a |
|
References
Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.