CVE-2026-8031

PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication

State
Published
Severity
6.9 Medium
Published
May 6, 2026
Updated
May 6, 2026
Reserved
May 6, 2026

Read the record on cve.org

Description

A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Scores

CVSSScoreVectorSource
4.06.9 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:PVulDB
3.15.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:CVulDB
3.05.3 MediumCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:CVulDB
2.05.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:OF/RC:CVulDB

Weaknesses

Affected Products

ProductVersions
e-Clinic Healthcare System ECHSPicoTronica
  • 5.7Affected
  • 5.7.1Not affected

References

Every record here comes from the CVE Program’s CVE List. © 1999–2026 The MITRE Corporation. CVE is a registered trademark of The MITRE Corporation. The records are reproduced under the CVE Program terms of use.