CVE-2026-8032

PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials

State
Published
Severity
6.9 Medium
Published
May 6, 2026
Updated
May 7, 2026
Reserved
May 6, 2026

Read the record on cve.org

Description

A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Scores

CVSSScoreVectorSource
4.06.9 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:PVulDB
3.17.3 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:CVulDB
3.07.3 HighCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:CVulDB
2.07.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:OF/RC:CVulDB

Weaknesses

Affected Products

ProductVersions
e-Clinic Healthcare System ECHSPicoTronica
  • 5.7Affected
  • 5.7.1Not affected

References