CVE-2026-9508

Incorrect Permission Assignment for Critical Resource vulnerability in Suprema's BioStar

State
Published
Severity
10.0 Critical
Published
May 29, 2026
Updated
May 29, 2026
Reserved
May 25, 2026

Read the record on cve.org

Description

Incorrect permission settings on a critical resource in Suprema BioStar 2 (versions 2.9.3 through 2.9.11) that allow backup files to be publicly exposed when the administrator configures their path within the NGINX webroot. This vulnerability allows an attacker with network access to directly download backup ZIP files via ‘http(s)://[server]/download/…’ without requiring authentication. This exposes highly sensitive information that can lead to server impersonation, unauthorized access to databases, and lateral movement.

Scores

CVSSScoreVectorSource
4.010.0 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:LINCIBE

Weaknesses

  • CWE-732 Incorrect Permission Assignment for Critical Resource

Affected Products

ProductVersions
BioStar 2 (server)Suprema
  • v2.9.3 through v2.9.11Affected
  • v2.9.12Not affected

References